Short answer
An Antalya solar consumption analysis examines, before the system is sized, 12 months of bills, hourly meter data where available, the day-night split, seasonality driven by the tourist season, contracted power and future loads together. Even when annual totals look close, monthly and hourly mismatches change the panel, inverter and battery decision; comparing against PVGIS monthly yield data makes that gap visible.
Key takeaways
- A design based only on total annual consumption overlooks mismatches within the day and across the months.
- Twelve months of bills reveal seasonality, while hourly meter data shows the day-night split.
- According to PVGIS 5.3, a 1 kWp system in central Antalya yields a theoretical 99 kWh in January and 168 kWh in July.
- The tourist season can push summer consumption above generation, which affects the battery and system type decision.
- Headroom for future loads such as electric vehicle charging and heat pumps should be planned from the start.
An Antalya solar consumption analysis is the work that establishes, before a solar power plant (GES) is sized, when a home or business uses electricity, how much it uses and which loads are responsible. Looking at total annual consumption may seem the quickest way to decide on the number of panels; but a design based only on that total ignores how generation and consumption overlap during the day and over the year. The right size, the right inverter and the right battery decision usually come from understanding that overlap.
In this article we explain step by step which data a consumption analysis for solar energy in Antalya relies on, why regional factors such as the tourist season matter, and how a sample consumption profile can be compared with PVGIS monthly yield data.
Why does an Antalya solar consumption analysis come before sizing?
The job of a solar plant is to cover as much of the electricity you need as possible from your own roof. If you install a system that is too small, your dependence on the grid remains higher than you expected. If you install a system far larger than you need, a significant share of the energy produced is not used at the moment of generation and therefore becomes dependent on the net metering rules, the battery capacity or the conditions for exporting to the grid. In both cases, the return on the investment falls.
A consumption analysis reduces that uncertainty. It lets you see together the months in which consumption peaks, the split between day and night, your contracted power and the loads to be added in the near future. We described the general approach to working out how many kW you need in our article how many kW of solar panels do I need; here we focus on the data behind that decision.
What data do you need?
The quality of the analysis depends on the quality of the data used. The more detailed the data you have, the more realistic the design will be.
Twelve months of billing history
The starting point is your electricity bills for the last 12 months. The monthly kWh consumption on the bills shows the seasonal fluctuation. A calculation based on a single month's bill is misleading; in Antalya, the difference in consumption between January and July is pronounced in many buildings. If your bill archive is incomplete, you can access your past consumption through the online service channels of the distribution company or your supplier.
Hourly or 15-minute meter data
A monthly bill answers the question "how much" but not "when". Especially for businesses and high-consumption customers, load profile data at hourly or shorter intervals, which can be obtained from the meter, reveals the consumption curve over the day. If this data is available, you can see directly how much load there is during the midday hours when the sun produces the most.
Load list and usage habits
If there is no meter data, a list of the main appliances and their hours of use provides a good approximation: air conditioners, pool pump, water heater, refrigeration units, kitchen equipment, production machinery. In homes, even who is at home during the day is an important piece of information.

The day-night split and self-consumption
Solar panels only generate during the day. How much of your consumption falls in daytime hours therefore directly affects the benefit the system will bring you. The share of generated energy that is used inside the building at the moment it is produced is called self-consumption. When self-consumption is high, most of the energy is put to use without going to the grid.
- Daytime-weighted profile: In businesses that operate during the day, such as offices, shops, workshops and cold stores, generation and consumption naturally overlap. An on-grid system is often sufficient.
- Evening-weighted profile: In homes that are empty during the day, consumption rises in the evening. In this case a hybrid solution with a battery or the net metering option is considered.
- Mixed profile: In hotels, guesthouses and holiday rental villas, daytime pool and air-conditioning loads combine with evening lighting and kitchen loads. Detailed data makes the biggest difference for this profile.
Some loads can be shifted in time. Moving flexible loads such as the pool pump, washing machine, water heating or vehicle charging to midday achieves higher self-consumption with the same system.
Seasonality and the tourist season in Antalya solar energy projects
Antalya has a consumption character of its own. Air-conditioning load rises in the summer months, and in tourist areas this rise becomes far more pronounced with the season. A hotel in Konyaaltı or Lara, a guesthouse in Manavgat or a holiday rental villa in Kaş can have a very different consumption profile in summer than in winter. You can find a detailed approach for tourism facilities in our article on solar energy for hotels and tourism facilities.
Solar generation also varies with the season, but not in exactly the same way as consumption. According to PVGIS 5.3 data, the theoretical monthly yield of a 1 kWp system in central Antalya is about 99 kWh in January and December, rising to 168 kWh in July. The theoretical annual total is around 1,656 kWh/kWp (assuming an optimum tilt of 33° and 14% system losses).
Sample comparison: PVGIS yield versus assumed consumption
The table below compares the theoretical monthly yield of a 10 kWp system in central Antalya, according to PVGIS 5.3, with the consumption of an assumed building whose consumption rises in the summer months. The consumption figures do not belong to a real customer; they were chosen solely to illustrate the logic of the analysis.
| Month | Theoretical yield, 10 kWp (kWh) | Assumed consumption (kWh) | Difference (kWh) |
|---|---|---|---|
| January | 990 | 1,100 | -110 |
| February | 1,080 | 1,000 | +80 |
| March | 1,420 | 900 | +520 |
| April | 1,500 | 900 | +600 |
| May | 1,570 | 1,200 | +370 |
| June | 1,590 | 1,700 | -110 |
| July | 1,680 | 2,100 | -420 |
| August | 1,670 | 2,100 | -430 |
| September | 1,550 | 1,500 | +50 |
| October | 1,370 | 1,000 | +370 |
| November | 1,140 | 950 | +190 |
| December | 990 | 1,150 | -160 |
| Total | 16,550 | 15,600 | +950 |
Because of rounding, the sum of the monthly values differs slightly from the PVGIS annual figure (16,560 kWh). The main message of the table is this: although the annual totals look close, generation exceeds consumption in spring and autumn, while consumption rises above generation in July and August. And this is only the monthly picture; within the day, night-time consumption does not overlap with generation at all. The annual total alone is therefore not enough to say "the system is sufficient".
How surplus generation is used and how the shortfall is covered depends on the net metering rules (mahsuplaşma, offsetting exported energy against imported energy) and on the system type. The period and conditions under which net metering applies are determined by the current regulations as of November 2026; we therefore confirm the current rules in our designs with sources from Akdeniz EDAŞ (the local electricity distribution company) and EPDK (the energy market regulator).
Contracted power and connection limits
Another part of the consumption analysis is the contracted power of your subscription and your connection conditions. The capacity of the solar power plant you can install is related to your existing connection capacity, the transformer capacity and current regulations. These limits may restrict the ideal system size shown by the consumption analysis, or they may bring up an additional step such as increasing the connection capacity. For details, see our article on connection capacity and transformers for Antalya solar power plants. Having the subscription details and contracted power from your bill ready before the site survey speeds up the process.
Account for future loads today
An Antalya solar energy system runs for many years, and your consumption may change over that time. When carrying out an Antalya solar consumption analysis, it is necessary to discuss not only today's bill but also the loads likely to be added over the next few years.
- Electric vehicle charging: If you plan to install a charging station at home or at work, the time of day when charging takes place affects the design.
- Heat pump: Switching to a heat pump for heating and hot water increases consumption, especially in winter. We covered this combination in our article on heat pumps and solar panels.
- Pool, extra floor or new unit: Adding a pool to a home, or commissioning a new production line in a business.
- Switching from gas to electricity: Moving to electric appliances in the kitchen or for hot water.
Even if these loads are not yet certain, the inverter selection and roof layout can be planned to allow panels to be added later. That way, the initial investment is made for today's needs while headroom for growth is preserved technically.

Carrying out the consumption analysis step by step when designing an Antalya solar plant
The consumption analysis approach we follow during Solar Nexo's free site survey can be summarized as follows:
- Collect the bills for the last 12 months and, if available, the meter load profile data.
- Compare monthly consumption with the theoretical monthly yield calculated by PVGIS.
- Estimate the shares of daytime and night-time consumption using meter data or the load list.
- Check the contracted power and connection conditions.
- List future loads and decide on the headroom for growth.
- Based on this data, compare on-grid, hybrid, off-grid and net metering system options.
If you would like to make an initial assessment yourself, you can use the calculator below. The tool provides a theoretical preliminary estimate; the final system size is determined through the site survey and a detailed analysis. For a more comprehensive calculation, you can also visit our solar energy calculator page.
How many kW do you need for your bill?Use the solar calculator to see system size, number of panels and annual production straight away.Conclusion
An Antalya solar consumption analysis is the foundation of a correctly sized system that pays off over the long term. When 12 months of billing history, hourly meter data where possible, the day-night split, regional seasonality such as the tourist season, contracted power and future loads are assessed together, the panel, inverter and battery decisions rest on solid ground. Even when annual totals look close, monthly and hourly differences determine the design. During the free site survey, the Solar Nexo team carries out this analysis with you based on your bills; for the general framework, you can also see the Antalya solar power plant guide.
Frequently asked questions
What documents are needed for a solar consumption analysis?
A solar consumption analysis requires at least the electricity bills for the last 12 months. The bills show monthly consumption and seasonal fluctuation. If available, load profile data at hourly or shorter intervals from the meter clarifies the day-night split. In addition, subscription details, contracted power and a list of the main appliances with their hours of use strengthen the analysis.
Is a system that generates as much as my annual consumption enough?
Not always, because even if the annual totals are equal, generation and consumption do not happen in the same months and hours. There may be a surplus in spring and a shortfall in summer and winter. Night-time consumption does not overlap with generation at all. How the surplus and shortfall are balanced depends on the system type, the battery capacity and the current net metering rules.
What is self-consumption and why does it matter?
Self-consumption is the share of the energy generated by solar panels that is used inside the building at the moment it is produced. When self-consumption is high, most of the energy generated is used without going to the grid, and the benefit of the system increases directly. Shifting flexible loads such as the pool pump, water heating or vehicle charging to midday is a practical way to raise self-consumption.
How does the tourist season affect solar plant design?
The tourist season directly affects solar plant design by significantly increasing summer consumption at hotels, guesthouses and holiday rental villas in Antalya. Solar generation also rises in summer, but not at the same rate as consumption. Seasonal facilities should therefore be analyzed with monthly and, where possible, hourly data, and the battery and system type decision should be based on that profile.
Can the analysis be done without meter data?
Yes, the analysis can be done without meter data, but the result will be more approximate. In that case, 12 months of bills and a load list with the power ratings and hours of use of the main appliances are used. Information such as who is at home during the day and when large loads like air conditioners and the pool pump run helps estimate the day-night split.
If I am thinking of buying an electric car, should I size the system up now?
You do not have to size it up now, but it is advisable to plan headroom for growth from the outset. The inverter selection and roof layout can be designed to allow panels to be added later. That way, the initial investment stays matched to today's consumption, and the system can be expanded once the car arrives. Charging time also matters: daytime charging increases self-consumption, while evening charging requires battery or grid support.
Does contracted power limit the size of a solar plant?
Yes, the contracted and connection capacity of the subscription is related to the solar plant capacity that can be installed and may limit the system size. The existing connection capacity, transformer capacity and current regulations are assessed together. If the size recommended by the consumption analysis exceeds these limits, an additional step such as increasing the connection capacity may be needed. The current rules should be confirmed with the distribution company and EPDK sources.
Sources