Maintenance and Efficiency · 9 min read

Antalya Solar Plant Performance Ratio: How to Measure PR and Yield

Is your plant really performing well? Antalya solar plant performance ratio and specific yield calculations, a comparison table with PVGIS monthly values and the checks to follow when PR is low.

Short answer

The Antalya solar plant performance ratio is the ratio of a plant's actual output to the energy it could theoretically produce from the irradiance reaching the panel surface. PR is found by dividing specific yield (kWh/kWp) by reference yield. Without an irradiance sensor, you can compare your output with PVGIS monthly values for Antalya, about 1,656 kWh/kWp a year. Persistent drops call for checks on soiling, shading, clipping and faults.

Key takeaways

  • PR = specific yield (kWh/kWp) ÷ reference yield (plane-of-array irradiation ÷ 1 kW/m²).
  • PR largely filters out the weather, making it possible to compare different months and plants.
  • Without a sensor, compare specific yield with PVGIS monthly values; this is not PR but a ratio to expected output.
  • A slight drop in PR in summer due to heat is normal.
  • Order of checks when PR is low: verify data, alarm history, string comparison, visual inspection, thermal scan, service.

“My plant produced 1,200 kWh last month — is that good?” The answer to this question is not in the kWh figure alone, because the same plant produces less in a cloudy month and more in a sunny one, and both can be perfectly normal. The Antalya solar plant performance ratio is the measure that shows how well a plant is really working by comparing its output with the solar energy that arrived during the same period. For a solar power plant (GES, from the Turkish güneş enerji santrali), this ratio filters out the effect of the weather and focuses on the real question: how much of the light it received did the plant manage to turn into electricity? In this article we explain how to calculate the performance ratio and specific yield, how to compare them with PVGIS values and what to do when the result is low.

What is the Antalya solar plant performance ratio (PR)?

The performance ratio (PR) is the ratio of a plant's actual output to the energy it could theoretically produce from the irradiance reaching the panel surface over the same period. It is expressed as a percentage or as a number between 0 and 1. Theoretical output is calculated from the panels' power under standard test conditions, so it represents an ideal, loss-free plant. Because a real plant has temperature, soiling, cable, inverter and shading losses, PR is never 100%.

The value of PR lies in being largely independent of the weather. In a cloudy month, both the incoming irradiance and the output fall; the ratio, however, stays similar as long as the plant is healthy. This lets you compare different months, different years and even different plants with the same yardstick.

Over the long term, PR also reflects the natural ageing of the panels. Panels lose power very slowly over the years, so a slight decline in the same plant's ratio spread across many years is to be expected. The limits of this decline are defined by the panel's performance warranty; for the panels supplied by Solar Nexo, this warranty is 30 years. Sudden, marked drops, on the other hand, cannot be explained by ageing and must always be investigated.

Specific yield and reference yield: three key concepts

To calculate the performance ratio, two intermediate values need to be defined first. The table below summarises these concepts.

ConceptHow is it calculated?UnitWhat does it tell you?
Specific yield (Yf)Actual AC output ÷ installed DC powerkWh/kWpHow much each 1 kWp of panels produced
Reference yield (Yr)Irradiation on the panel plane ÷ 1 kW/m²hours (kWh/kW)Equivalent hours of the panels running at full power
Performance ratio (PR)Yf ÷ Yr% or 0–1How much of the incoming light was turned into electricity

Specific yield lets you evaluate a plant independently of its size: a 10 kWp villa system and a 500 kWp commercial plant can be compared on a kWh/kWp basis. Specific yield does, however, depend on the weather. Reference yield requires the irradiance on the panel plane to be measured, which is usually done with a pyranometer or a reference cell mounted at the panel tilt.

Calculating the Antalya solar plant performance ratio: a step-by-step example

The example below is based entirely on theoretical assumptions and is given only to illustrate the method.

  1. Know the installed capacity: Assumption: a 10 kWp plant.
  2. Take the output for the period: Assumption: AC output read from the meter over one month is 1,500 kWh.
  3. Calculate the specific yield: 1,500 ÷ 10 = 150 kWh/kWp.
  4. Take the irradiation: Assumption: total irradiation measured on the panel plane in the same month is 190 kWh/m². This corresponds to a reference yield of 190 hours.
  5. Calculate PR: 150 ÷ 190 ≈ 0.79, or about 79%.

Without an irradiance sensor you cannot calculate the true PR, but you can obtain a practical indicator by comparing specific yield with the value expected by PVGIS. This comparison is not PR; it should be thought of as a “ratio to expected output”. For example, again as an assumption, if you produced 150 kWh/kWp in July and PVGIS forecasts 168 kWh/kWp for that month, the ratio is 150 ÷ 168 ≈ 89%. When interpreting the result, you should also consider whether that month was cloudier or dustier than usual.

Close-up view of solar panel cells and frame
General illustration representing the condition of the panel surface

Comparing monthly output with PVGIS values for Antalya

In the theoretical PVGIS 5.3 calculation that illustrates the potential of solar energy in Antalya, a 1 kWp system at optimum tilt (33°), assuming 14% system losses, generates about 1,656 kWh per year in central Antalya. Losses are already assumed within this value, so it can be compared directly with specific yield. In the table below you will find the monthly values and the theoretical expectation for a hypothetical 10 kWp plant. You can fill in the last column with your own measurements.

MonthPVGIS (kWh/kWp)Theoretical expectation for 10 kWp (kWh)Your measurement (kWh)
January99990…
February1081,080…
March1421,420…
April1501,500…
May1571,570…
June1591,590…
July1681,680…
August1671,670…
September1551,550…
October1371,370…
November1141,140…
December99990…
Year≈1,656≈16,560…

This table assumes optimum tilt and a south orientation. If your roof has a different pitch or an east-west orientation, you need to enter your own tilt and orientation values into PVGIS to calculate a monthly expectation specific to you. The annual values also differ for Alanya (1,615), Manavgat (1,649), Kaş (1,664), Korkuteli (1,655) and Elmalı (1,719 kWh/kWp per year). If you would like to run a preliminary calculation for your own system, you can use our solar energy calculator.

Losses that lower PR at solar power plants in Antalya

When a plant's ratio drops, the cause is usually one or more of the following types of loss:

  • Temperature: Panel efficiency falls as cell temperature rises. That is why, in Antalya's hot summer months, PR can come out lower than in the cooler spring and autumn months even though kWh output is high. This seasonal fluctuation is normal.
  • Soiling: Dust, pollen, bird droppings and, near the coast, salt deposits reduce the light reaching the panel. The effect becomes noticeable during long dry spells. For cleaning methods, see our article on solar panel cleaning.
  • Shading: A tree that has grown since installation, a new building or equipment added to the roof can create shading losses that did not exist at installation.
  • Inverter clipping: If the DC panel power is high relative to the inverter's AC power, the inverter output is capped during the hours of strongest irradiance.
  • Electrical losses: Cable resistance, small differences between panel ratings and contact problems at connection points.
  • Unavailability: Hours during which the inverter is out of service due to a fault, a communication problem or grid-related causes are a direct loss.

We cover in detail how each of these losses arises in our article on the causes of low solar panel efficiency. The aim of this article, by contrast, is to measure the loss and decide where to look.

What to do when the performance ratio is low: the order of checks

There is no need to panic when you see the ratio falling below expectations; a systematic order of checks usually reveals the cause quickly.

  1. Verify the data: Compare the output in the inverter portal with the meter reading. Days with data loss or power cuts can distort the result.
  2. Check the alarm history: Look in the inverter's error logs for insulation, grid voltage or communication warnings.
  3. Compare the strings: Strings with the same orientation and tilt should produce similar amounts. A string that is clearly lower shows where the problem is.
  4. Carry out a visual inspection: Is there soiling, shading, broken glass, discolouration or a loose cable?
  5. Have a thermal scan done: Hot spots, failed bypass diodes or overheating connections show up on a thermal camera. For the method, see our article on panel inspection with a thermal camera.
  6. Call in service: Where measurements and tests are required, an authorised technical team should step in.

Solar Nexo provides maintenance and repair not only for the plants it builds but also for systems installed by other companies. The replacement of 5 failed inverters at an existing plant in Gazipaşa, built by another company, is one example of this kind of service work.

Inverter replacement service at an existing solar plant in Gazipaşa
Solar Nexo's inverter replacement service at a plant in Gazipaşa built by another company

Measurement reliability: which data should you trust?

A correct evaluation needs correct data. On the output side, meter data is generally considered more reliable than inverter data, since the inverter's own measurement can show small deviations. On the irradiance side, the sensor must be mounted at the same tilt and orientation as the panel plane, kept clean, and have its calibration checked at the intervals recommended by the manufacturer. A dirty sensor shows irradiance as lower than it really is and artificially inflates PR. Because in the dry summer months dust soils not only the panels but also the sensors, tying sensor cleaning to the same schedule as panel cleaning is good practice at sites that harvest solar energy in Antalya.

Choosing the right evaluation period also matters. Daily PR fluctuates because of passing clouds and data delays; monthly and annual values are more meaningful. Comparing the same month of the year with previous years helps distinguish the natural ageing of the panels from persistent problems. We explain how this data is collected and reported for plants at operating scale in our article on solar plant remote monitoring.

Conclusion

The Antalya solar plant performance ratio is the clearest way to assess your plant's health independently of the weather. If you have an irradiance sensor, you can calculate PR directly; if not, you can obtain a practical indicator by comparing your specific yield with PVGIS monthly values. A slight drop in the ratio in summer because of the heat is normal; however, persistent and unexplained declines should be investigated for causes such as soiling, shading, clipping or faults. Every solar power plant in Antalya benefits from this kind of regular review, and solar energy in Antalya is abundant enough that lost output is worth tracking down. If you would like your plant's output evaluated, you can contact the Solar Nexo team together with your monitoring data. For the general framework, have a look at our Antalya solar power plant guide.

Frequently asked questions

What is the performance ratio (PR)?

The performance ratio is the ratio of a solar plant's actual output to the energy it could produce under ideal, loss-free conditions from the irradiance reaching the panel surface over the same period. It is expressed as a percentage and, because it largely filters out the effect of the weather, makes it possible to compare different months, years and plants. Since a real plant has temperature, soiling, cable and inverter losses, the ratio is never 100%.

What is the difference between specific yield and performance ratio?

Specific yield is found by dividing the energy produced by the installed capacity and is expressed in kWh/kWp; it depends on the weather. The performance ratio is specific yield divided by the reference yield, which is based on the irradiance reaching the panel plane. In other words, specific yield shows how much you produced, while the performance ratio shows how well you used the incoming light. Calculating PR requires irradiance measurement.

How can I evaluate my plant without an irradiance sensor?

Without an irradiance sensor you cannot calculate the true performance ratio, but you can compare your specific yield with the monthly value expected by PVGIS. For central Antalya, the theoretical PVGIS 5.3 value is 1,656 kWh/kWp per year, 168 kWh/kWp in July and 99 in December. If your roof's tilt and orientation differ, you should enter your own values into PVGIS. This comparison is an indicator; a cloudier-than-usual month can affect the result.

Why does the performance ratio drop in summer when output is high?

In summer, irradiance and therefore kWh output are high, but panel efficiency falls as cell temperature rises. As a result, the performance ratio in hot summer months can come out somewhat lower than in the cooler spring and autumn months. This seasonal fluctuation is normal. Leaving room for air circulation behind the panels and choosing panels with a low temperature coefficient help limit this effect.

What should I do first if the performance ratio is low?

The first step is to verify the data: compare the output in the inverter portal with the meter reading and set aside days with data loss or power cuts. Then check the inverter's alarm history, compare the output of strings with the same orientation and tilt, and visually inspect the panels for soiling and shading. If no cause is found, a thermal scan and measurements by an authorised technical team should follow.

How often should I evaluate the performance ratio?

Because daily values fluctuate with passing clouds and data delays, it is more meaningful to evaluate the performance ratio monthly and annually. Comparing the same month with previous years helps distinguish the natural ageing of the panels from persistent problems. At plants of operating scale, monitoring systems can be configured to calculate this value automatically and raise an alarm when it falls below a defined threshold.

Sources

  1. PVGIS – European Commission JRC
  2. Turkish State Meteorological Service (MGM)

Want a clear calculation for your roof?

The Solar Nexo team carries out a free site survey at your address in Antalya and designs the system that suits your roof, consumption and budget.

Read these next

Related articles

Antalya Solar Energy Systems

We are opening the doors of the future with solar energy

Call now or fill in the form for detailed information and a free site survey; we come to every corner of Antalya.

+90 540 007 63 96